configure msrp timers first-value-change-recovery

configure msrp timers first-value-change-recovery [first_value_change_msec | off]

Description

This command configures MSRP first value change recovery timer, or disables the timer. If configured, the system waits until the configured timer value before allowing recovery of streams from first value change failure. If disabled, the system does not recover from first value change failure.

Syntax Description

msrp Multiple Stream Registration Protocol.
timers Multiple Stream Registration Protocol timers.
first-value-change-recovery The time interval to wait to allow recovery of stream from first value change failure.
first_value_change_msec First Value Change Recovery time in milliseconds (range is 10000 ms to 5400000 ms, default is 30000 ms); type="uint32_t"; range="[10000, 5400000]".
off Turn off first value change recovery timer, and do not recover from first value change failure.

Default

30000 ms.

Usage Guidelines

Use this command to allow streams to recover from first value change failure.

Example

# configure msrp timers first-value-change recovery 20000
# configure msrp timers first-value-change recovery off

History

This command was first available in ExtremeXOS 15.3.2.

Platform Availability

This command is available on platforms that support the AVB feature pack license and have it installed. For complete information about software licensing, including how to obtain and upgrade your license, and which platforms support the AVB feature, see the Switch Engine v33.1.1 Licensing Guide document.